DUOYI DY518 refrigerant table is is a necessary tool for testing and maintenance of refrigeration equipment such as air conditioners, fridge and cold storage. It comes with three main functions with testing, digital readings and multi-unit switching. Built in 89 types refrigeration database drives it provide much more accurate readings. Help you more convenient for refrigeration system installation or servicing
Buy now and we will give you a door and window support positioning airbag as a gift for your order.
To better suit your needs and preferences, DUOYI has developed several different digital manifold gauges and related tools. To allow you to choose and purchase the right product faster, we provide purchase links for the corresponding products. If necessary, you can click on the corresponding product link below to learn more!
DUOYI DY518 Digital Manifold Gauge>>
DUOYI DY517A Digital Manifold Gauge Set>>
DUOYI DY522A Digital Manifold Gauge Set>>
DUOYI DY5750B Car Air Conditioner Leak Detector>>
DUOYI HVAC Temperature Control Clamp>>
R1234YF-R134a conversion connector>>
- DY518 Digital Manifold Gauge Description: 【Upgrade Equipment】: DY518 HVAC digital manifold meter built-in 32-bit digital processing unit and high precision data acquisition unit make instrument efficient and stable. 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data, which is available to work for automobile air conditioner, household air conditioning, cold storage, and refrigeration equipment. 【Multiple Function】: DY518 digital refrigerant gauge great tool for refrigeration charging and pulling vacuum. The pressure test, evaporation temperature test, and condensation temperature test can be performed at the same time when filling the refrigerant. As well as real-time display of current vacuum pressure and percentage of the vacuum level. 【LCD Backlight Display】: Our air conditioning maintenance tool come with LCD large size liquid crystal screen, data display clear and easy to read, short-press the power key for 2 seconds switch the backlight on and off. And by default,the system automatically turns off after 10 minutes of inactivity. You can set to cancel the auto power off function. 【Multiple Units Switchable】: The DY518 freon temperature tester come with multi-unit conversion function, KPa, Bar, PSI, InHg, MPa, Celsius, Fahrenheit, which can be easily switched as required and meet you different needs. 【Thoughtful Design】: DY518 manifold pressure gauge uses High-strength engineering plastic and flexible non-slip silicone design make instrument solid and comfortable to hold. The foldable hook assures a secure attachment of the digital manifold for care-free and hands-free, let you free your hands to concentrate on testing.
- Digital Manifold Gauge Specifications: Material: ABS Pressure Test Unit: Kpa; Mpa; bar; inHg; PSI. Pressure Test Range: 0Kpa – 6000Kpa Pressure Test Resolution: 1Kpa Pressure Test Accuracy: ±0.5 %(FS)+ 5dgt Pressure Overload Limit: 10000 Kpa (10 Mpa; 100 bar;) Vacuum Test: Relative Vacuum Vacuum Test Range: -101Kpa – 0Kpa Temperature Test Unit: °C (Celsius), °F (Fahrenheit) Temperature Test Range: -40°C–150°C (-40°F–302°F) Temperature Test Resolution: 0.1°C (-40°C–99.9°C), 1°C (100°C–150°C) / 0.1°F (-40°F–99.9°F), 1°F (100°F–302°F) Temperature Test Accuracy: ±0.5°C + 2dgt,±0.9°F + 2dgt Power Supply: 4 x 1.5V AA / LR6 (Battery not include) Dimension: 4.33 x 7.28 x 1.69″ Weight: 1.32 lbs
- Package Includes: 1 x DY518 Manifold Pressure Gauge 1 x Packing Box 1 x Carry Bag 1 x User Instruction
- Notices: Please operate in accordance with the operating instructions or the professional personnel guide. Before using the HVAC guage, please make sure that refrigerant hoses and temperature sensor clamps are connected properly. Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Please wear qualified protective equipment to protect user during testing. Please handle gently to avoid shock and fall. After use, please close all the buttons to improve the service life. Plug the joint when not in use, to prevent foreign bodies from entering, please clean and regularly replace the refrigerant tube, remove dirt and impurities in the valve. The pressure gauge is a perishable product, you need to check it regularly to ensure its accuracy. Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
- Please operate in accordance with the operating instructions or the professional personnel guide.
- Before using the HVAC guage, please make sure that refrigerant hoses and temperature sensor clamps are connected properly.
- Please confirm the rated pressure value of the tested equipment before testing.
- Do not use it if it exceeds the range of the instrument. Please wear qualified protective equipment to protect user during testing.
- Please handle gently to avoid shock and fall. After use, please close all the buttons to improve the service life.
- Plug the joint when not in use, to prevent foreign bodies from entering, please clean and regularly replace the refrigerant tube, remove dirt and impurities in the valve.
- The pressure gauge is a perishable product, you need to check it regularly to ensure its accuracy.
- Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.